RTEMS 6.1-rc6
|
Macros | |
#define | PWR_PVDLEVEL_0 PWR_CR1_PLS_LEV0 |
#define | PWR_PVDLEVEL_1 PWR_CR1_PLS_LEV1 |
#define | PWR_PVDLEVEL_2 PWR_CR1_PLS_LEV2 |
#define | PWR_PVDLEVEL_3 PWR_CR1_PLS_LEV3 |
#define | PWR_PVDLEVEL_4 PWR_CR1_PLS_LEV4 |
#define | PWR_PVDLEVEL_5 PWR_CR1_PLS_LEV5 |
#define | PWR_PVDLEVEL_6 PWR_CR1_PLS_LEV6 |
#define | PWR_PVDLEVEL_7 PWR_CR1_PLS_LEV7 |
#define PWR_PVDLEVEL_0 PWR_CR1_PLS_LEV0 |
Programmable voltage detector level 0 selection : 1V95
#define PWR_PVDLEVEL_1 PWR_CR1_PLS_LEV1 |
Programmable voltage detector level 1 selection : 2V1
#define PWR_PVDLEVEL_2 PWR_CR1_PLS_LEV2 |
Programmable voltage detector level 2 selection : 2V25
#define PWR_PVDLEVEL_3 PWR_CR1_PLS_LEV3 |
Programmable voltage detector level 3 selection : 2V4
#define PWR_PVDLEVEL_4 PWR_CR1_PLS_LEV4 |
Programmable voltage detector level 4 selection : 2V55
#define PWR_PVDLEVEL_5 PWR_CR1_PLS_LEV5 |
Programmable voltage detector level 5 selection : 2V7
#define PWR_PVDLEVEL_6 PWR_CR1_PLS_LEV6 |
Programmable voltage detector level 6 selection : 2V85
#define PWR_PVDLEVEL_7 PWR_CR1_PLS_LEV7 |
External input analog voltage (Compare internally to VREF)