RTEMS Logo

RTEMS 4.9.2 On-Line Library


Task Manager Floating Point Considerations

PREV UP NEXT Bookshelf RTEMS Ada User's Guide

5.2.7: Floating Point Considerations

Creating a task with the RTEMS.FLOATING_POINT attribute flag results in additional memory being allocated for the TCB to store the state of the numeric coprocessor during task switches. This additional memory is NOT allocated for RTEMS.NO_FLOATING_POINT tasks. Saving and restoring the context of a RTEMS.FLOATING_POINT task takes longer than that of a RTEMS.NO_FLOATING_POINT task because of the relatively large amount of time required for the numeric coprocessor to save or restore its computational state.

Since RTEMS was designed specifically for embedded military applications which are floating point intensive, the executive is optimized to avoid unnecessarily saving and restoring the state of the numeric coprocessor. The state of the numeric coprocessor is only saved when a RTEMS.FLOATING_POINT task is dispatched and that task was not the last task to utilize the coprocessor. In a system with only one RTEMS.FLOATING_POINT task, the state of the numeric coprocessor will never be saved or restored.

Although the overhead imposed by RTEMS.FLOATING_POINT tasks is minimal, some applications may wish to completely avoid the overhead associated with RTEMS.FLOATING_POINT tasks and still utilize a numeric coprocessor. By preventing a task from being preempted while performing a sequence of floating point operations, a RTEMS.NO_FLOATING_POINT task can utilize the numeric coprocessor without incurring the overhead of a RTEMS.FLOATING_POINT context switch. This approach also avoids the allocation of a floating point context area. However, if this approach is taken by the application designer, NO tasks should be created as RTEMS.FLOATING_POINT tasks. Otherwise, the floating point context will not be correctly maintained because RTEMS assumes that the state of the numeric coprocessor will not be altered by RTEMS.NO_FLOATING_POINT tasks.

If the supported processor type does not have hardware floating capabilities or a standard numeric coprocessor, RTEMS will not provide built-in support for hardware floating point on that processor. In this case, all tasks are considered RTEMS.NO_FLOATING_POINT whether created as RTEMS.FLOATING_POINT or RTEMS.NO_FLOATING_POINT tasks. A floating point emulation software library must be utilized for floating point operations.

On some processors, it is possible to disable the floating point unit dynamically. If this capability is supported by the target processor, then RTEMS will utilize this capability to enable the floating point unit only for tasks which are created with the RTEMS.FLOATING_POINT attribute. The consequence of a RTEMS.NO_FLOATING_POINT task attempting to access the floating point unit is CPU dependent but will generally result in an exception condition.


PREV UP NEXT Bookshelf RTEMS Ada User's Guide

Copyright © 1988-2008 OAR Corporation